ECG-101 Digital
Single Channel ECG (CE Certification of
Conformity) |
|
Features £º
High resolution thermal printing array system
High frequency response reach to 150Hz
Capable of printing continuous one channel trace and annotations
including lead mark
and such parameters as sensitivity, paper speed, and filter
operation status.
High resolutioin digital filter inhibits baseline drift without
distorting ECG wave-form.
One-touch operation able to enhance efficiency and relieve operating
strain.
Concept of floating input circuit meets IEC safety standard.
Visual status due to light indicated touch-keys.
Rechargeable battery supporting more than 50 patient examinations.
Under the automatic mode, pressing key ¡°MODE¡± continuously can keep
recording
when abnormal lead is found. |
|
Specifications:
|
leads |
Standard 12 leads |
|
Input
Circuit |
Floating; Protection against defibrillation
effect |
|
Input
Impedance |
>50M¦¸ |
|
Output Impedance |
<100¦¸ |
|
Patient
current leakage |
<10¦ÌA |
|
Input Circuit Current |
¡Ü0.1¦ÌA |
|
Calibrating Voltage |
1mV¡À5% |
|
Output
Voltage |
0.5/mV¡À5% |
|
A/D Conversion |
12 bit |
|
Frequency Response |
0.05¡«150Hz |
|
Time Constant |
>3.2s |
|
CMRR |
>80dB >100dB(with AC filter) |
| EMG Filter |
35Hz(-3dB)/25Hz(-3dB) |
|
Standard Sensitivity |
10mm/mV¡À0.2mm/mV |
|
Sensitivity Setting |
5¡¢10¡¢20mm/mV, conversion deviation¡Ü5% |
|
Skin Voltage Tolerance |
¡À300mV |
| Noisy Level |
¡Ü15¦ÌVp-p |
|
Common Mode |
>80dB |
|
Rejection Rate |
>100dB (rejection
controller) |
|
Power
supply |
AC:
220/110V, 50/60Hz,15VA DC: 12V rechargeable
battery |
|
Safety standard |
IEC class I, type CF |
|
Recording System |
Thermal-array printing
system |
|
Printing speed |
25¡¢50mm/s¡À3% |
|
Recording Paper |
high-speed roll
50mm¡Á20m |
|
Input
circuit |
¡Ü50nA |
|
Dimensions |
(L¡ÁW¡ÁH)
31¡Á23¡Á7cm |
|
Dimension of package |
(L¡ÁW¡ÁH) 40¡Á28¡Á17cm |
|
Net
weight |
2.7
KGS |
|
Gross
weight |
4.5
KGS |
¡¡ |
¡¡¡¡ |
 ¡¡ |
ECG-101G Digital
Single Channel ECG |
Features
£º
-
High resolution
thermal printing array
system
- High
frequency response reach to 150Hz
- Rhythm Lead
selectable
- LCD Brightness
adjustable
- Capable of printing continuous one channel trace and
annotations including lead mark
and such parameters as
sensitivity, paper speed, and filter operation
status
- High resolutioin
digital filter inhibits baseline
- One-touch operation able to enhance efficiency and
relieve operating strain.
- Concept of floating input circuit meets IEC safety
standard.
- Visual status due to light indicated
touch-keys.
- Rechargeable battery supporting more than 50 patient
examinations.
- Under the automatic mode, pressing key ¡°MODE¡±
continuously can keep recording
when abnormal lead is
found.
- The wave-form is
displaying synchronously on the LCD with CCFL 240¡Á128 dots
¡¡ |
|
Specifications:
|
leads |
Standard 12 leads |
|
Input
Circuit |
Floating; Protection against defibrillation
effect |
|
Input
Impedance |
>50M¦¸ |
|
Output Impedance |
<100¦¸ |
|
Patient
current leakage |
<10¦ÌA |
|
Input Circuit Current |
¡Ü0.1¦ÌA |
|
Calibrating Voltage |
1mV¡À5% |
|
Output
Voltage |
0.5/mV¡À5% |
|
A/D
Conversion |
12 bit |
|
Frequency Response |
0.05¡«150Hz |
|
Time Constant |
>3.2s |
|
CMRR |
>80dB >100dB(with AC filter) |
| EMG Filter |
35Hz(-3dB)/25Hz(-3dB) |
|
Standard Sensitivity |
10mm/mV¡À0.2mm/mV |
|
Sensitivity Setting |
5¡¢10¡¢20mm/mV, conversion deviation¡Ü5% |
|
Skin Voltage Tolerance |
¡À300mV |
| Noisy Level |
¡Ü15¦ÌVp-p |
|
Common Mode |
>80dB |
|
Rejection Rate |
>100dB (rejection
controller) |
|
Power
supply |
AC:
220/110V, 50/60Hz,15VA DC: 12V rechargeable
battery |
|
Safety standard |
IEC class I, type CF |
|
Recording System |
Thermal-array printing
system |
|
Printing speed |
25¡¢50mm/s¡À3% |
|
Recording Paper |
high-speed roll
50mm¡Á20m |
|
Input
circuit |
¡Ü50nA |
|
Dimensions |
(L¡ÁW¡ÁH)
31¡Á23¡Á7cm |
|
Dimension of package |
(L¡ÁW¡ÁH) 40¡Á28¡Á17cm |
|
Net
weight |
2.9
KGS |
|
Gross
weight |
4.7
KGS |
¡¡ |
¡¡¡¡ |
 |
|
ECG-9801 Digital Single
Channel ECG |
Feature£º
-
Wide screen LCD with
two anto operation modes, Chinese/English interchange
¡¡
- Auto recall of previous operation mode and paper feeding speed
¡¡
- Compatible of coil paper and folded sheet
- Lead II with
rhythm lead printing mode, non-stop printing mode, auto ID & ID
zeroing
¡¡
- Built-in Li-ion rechargeable battery, above 100 minutes continuous
work when it is full and
no-operation auto shutdown within 10 minutes
¡¡
- High-grade technological design
¡¡
- Smart appearance with the weight of 2 Kgs ensures higher portability
and operation simplicity, suitable for varied occasions
¡¡
-
Built-in digit filter
can clear up interference from AC, EMG and DFT
¡¡ |
¡¡ |
 |
ECG-300 Digital Three Channel
ECG |
Features£º
- High resolution
thermal printing system, high precision.
- 12 leads collection
in phase as well as 3 leads printing in phase.
- Digital design and
filter, baseline auto-adjustable.
- LCD displays
operation menu. DC/AC auto-exchange.
- Automatic
measurement, analysis and diagnosis with high speed.
- Elegant and
compact outlook£¬with inner
handhold.
¡¡ |
|
Specifications:
| Lead
Standard |
12
leads |
| Input Circuit |
Floating; Protection against defibrillator
effect |
| Input Impedance |
£¾50M¦¸ |
| Output Impedance |
£¼100¦¸
|
| Patient Current Leakage |
£¼10¦ÌA |
| Input Cirput Current |
¡Ü0.1¦ÌA |
|
Calibrating Voltage |
1mV¡À5% |
| A/D Conversion |
12 bit |
| Frequency Response |
0.05¡«150Hz |
| Time
Constant |
£¾3.2s |
| CMRR |
£¾80dB £¾100dB(with AC
filter) |
| EMG
Filter |
35Hz(-3dB)/25Hz(-3dB) |
| Standard Sensitivity |
10mm/mV¡À0.2mm/mV |
| Sensitivity Selection |
5¡¢10¡¢20mm/mV, conversion deviation¡À5% |
| Skin
Voltage Tolerance |
¡À300mV |
| Noise Level |
¡Ü15¦ÌVp-p |
| Baseline Control |
Auto-adjustable |
| External DC Input |
10mm/V¡À5©‡,one
end¡Ý100 K¦¸ |
| ECG
Output |
1V/mV¡À5©‡,one
end¡Ü100¦¸ |
| Power Supply |
AC£º220/110V,50/60Hz,15VA DC£º12V
rechargeable battery |
| Safety Standard |
IEC
class¢ñ,type CF |
| Operation Method |
Auto
or manual |
| Analysis Function |
ECG
parameters auto-measure,auto-analysis |
| Recording System |
Thermal-array printing system |
| Paper Speed |
25¡¢50mm/s¡À5©‡ |
| Recording Paper |
High-speed roll 63mm¡Á30m |
Dimensions
|
(L¡ÁW¡ÁH)310mm¡Á230mm¡Á70mm |
| Dimensions of Packing |
(L¡ÁW¡ÁH)400mm¡Á280mm¡Á170mm |
| Net
Weight |
2.8kg |
| Gross Weight |
4.6kg |
¡¡ |
¡¡ |
|
¡¡ |
 |
|
ECG-9803 Digital Three Channels
ECG |
Feature£º
-
Real time 3 channel print
out
Roll/Zip fold thermal recording paper of 63mm in width for real time 3
channel print out of ECG trace, measurement and interpretation
¡¡
- Arrhythmia detection
Able to detect arrhythmia by analyzing 100 heartbeats and output
compressed ECG traces and interpretation of R-R interval
¡¡
- Standard 3 channel print out
¡¡
- Interpretation of long R-R interval
¡¡
-
High Quality Technology
Small weight, grace appearance, and portable design make the unit easy
to operate and applicable to different circumstances
¡¡
-
Communication with PC
Capable of communicating with PC, through the built in RS232 interface,
for further viewing and management of standard ECG trace and
interpretation
¡¡
- Unique digital filter
Specially designed digital filter for effective elimination of
interference concerning AC, EMG and baseline drift
-
Built in rechargeable
Lithium battery
¡¡ |
¡¡
¡¡ |
 |
|
ECG-1200 Digital Twelve Channels
ECG |
Feature£º
- Simultaneous 12
leads acquisition and printing
- Automatic measurement and
interpretation; R-R analysis
¡¡
- 12 leads simultaneous display on
large backlight
LCD 320¡Á240
¡¡
- Digital design and filter; Thermal
array printer
¡¡
- Recording on A4 size paper
¡¡
- Baseline auto-adjustable; Rhythm
lead selectable
¡¡
- DC/AC autoexchange, built-in
rechargeable battery. Power supports continuously working for more than
50 patients
¡¡
- 16 pieces of unzipped ECG data and
waveforms are stored for copy and re-call
¡¡
- Inner handhold designed for
portability
Standard Accessories:
Patient Cable,Thermal Printing Paper, Limb Electrodes, Chest
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Electrodes,
Electric Gel, Power Supply Cable, Grounding Wire
¡¡ |